Dairy Processor Training Schematic

Dairy Processor Training Schematic

Milk Tanker Truck Sampling

Installed via a QualiTru Sanitary Recessed Port with Security Lid, an official Pasteurized Milk Ordinance (PMO) Appendix N (antibiotic) sample can be obtained at the processing plant without the need to climb to the top of the milk tanker truck, assuring a safer physical sampling environment for certified samplers.

Learn about QualiTru products.

Recessed Port with Security Lid SOP

Installed at the outlet valve of a tanker truck via a beveled seat Qualitru TruStream Sanitary Port.  A representative sample of the milk in the milk tanker truck can be collected via a peristaltic pump and sterile collection bag as the truck is being unloaded in the receiving bay.

Raw Product Sampling

Installed via a QualiTru TruStream Sanitary Recessed Port in the raw receiving silo for regulatory or milk quality samples.

Learn about QualiTru products.

Silo Sampling SOP

System Diagnostic

Installed via a QualiTru TruStream Sanitary Port at any location throughout your fluid path as part of the diagnostic function, system quality check, CIP cleanliness check and overall milk quality samples.

Learn about QualiTru products.

Guidelines for System Diagnostic Sampling and Process Verification

System Diagnostic

Installed via a QualiTru TruStream Sanitary Port before or after each piece of equipment as part of a system diagnostic function, system quality check, CIP cleanliness check and overall milk quality samples.

Learn about QualiTru products.

Guidelines for System Diagnostic Sampling and Process Verification

Post-Pasteurization Monitoring

Installed via a QualiTru TruStream Sanitary Port on the back side of the pasteurizer to monitor post-pasteurization contamination and to verify pasteurization effectiveness and efficiency. Can also be a part of the diagnostic function, system quality check, CIP cleanliness check and overall milk quality samples.

Learn about QualiTru products.

Guidelines for System Diagnostic Sampling and Process Verification

Dairy Processor Training pipes
MilkORCheeseORCultured
(click an option above)
Dairy Processor Milk

Pasteurized Holding Tank

Installed via a QualiTru TruStream Sanitary Recessed Port in the finished goods/ pasteurized tank or silo to obtain regulatory or quality system samples.

Learn about QualiTru products.

Silo Sampling SOP

Filler

Installed via a QualiTru TruStream Sanitary Port just prior to the filler for regulatory or quality system samples. Samples can also be used to verify quality prior to packaging and also to verify the lack of contaminants system-wide.

Learn about QualiTru products.

Guidelines for System Diagnostic Sampling and Process Verification

Dairy Processor Cheese

Inoculating

Installed via a QualiTru TruStream Sanitary Tank Port or Recessed Port on the exterior of the vat.  This allows access to inoculate the milk with the specific cultures while still keeping the system closed from the environment. This unique approach helps to mitigate the risk of unwanted microorganisms from entering the vat and contaminating the product.

Learn about QualiTru products.

Whey Analysis

Installed via a QualiTru TruStream Sanitary Port off the vat outlet valve and prior to the whey storage tank or silo for regulatory or quality samples.

Learn about QualiTru products.

Line Sampling SOP

Dairy Processor Cultured

Bulk Starter Tank

Installed via a QualiTru TruStream Sanitary Tank Port or Recessed Port on the exterior of the tank or silo.  This gives you access to inoculate the milk with specific cultures, while still keeping the system closed from the environment. The unique approach helps to mitigate the risk of unwanted microorganisms from entering the vat and contaminating the product. Can also be used to take quality or regulatory samples.

Learn about QualiTru products.

Bulk Tank & Silo Sampling SOP

Incubation Tank

Installed via a QualiTru TruStream Sanitary Port on the side of the incubation tank to obtain quality or process samples.

Learn about QualiTru products.

Bulk Tank & Silo Sampling SOP

After The Plate Cooler or Chiller

Installed via a QualiTru TruStream Sanitary Port (either elbow or straight), we recommend it be installed as close to the chiller outlet as possible. A peristaltic pump should be located as close to the QualiTru TruStream Sanitary Port as possible. Samples can be used to monitor regulatory and quality. Can also be used for troubleshooting quality and cleaning issues when installed in a series.

Learn about QualiTru products.

Guidelines for System Diagnostic Sampling and Process Verification

Diagnostic

Installed via a QualiTru TruStream Sanitary Port at any location throughout your fluid path as part of a diagnostic function, system quality check, CIP cleanliness check and overall milk quality samples.

Learn about QualiTru products.

Guidelines for System Diagnostic Sampling and Process Verification

Filler

Installed via a QualiTru sanitary port just prior to the filler for regulatory or quality system sampling. Samples can also be used to verify sterility of product just prior to packaging and to verify the lack of contaminants system-wide.

Learn about QualiTru products.

Line Sampling SOP